Scientific equipment for climate research, industrial measurements and air quality analysis

NIKIRA LABS PORTABLE GAS ANALYZERS

High-performance, compact, and cost-effective gas measurements for climate change related research, e.g. landfill methane emissions or soil flux measurement, as well as industrial application such as semiconductor FAB AMC detection.

Cavity-Enhanced Absorption Spectrometry (CEAS/ICOS) technology represents the latest advance in tunable diode laser absorption spectroscopy and delivers superior performance and reliability, yet is orders-of-magnitude less sensitive to internal alignment of components and to variations in local temperature and pressure. As a result, CEAS is ideal for use in commercial instruments for even the most demanding applications in remote and/or hazardous locations. Its superior performance results in:

  • high sensitivity; detect contaminants at ppt/ppb levels (due to long optical pathlength by using high reflectivity mirrors)
  • high accuracy (minimal cross-interference through the use of high-resolution diode laser absorption technology, low pressure and algorithms)
  • fast T90 (<10-30 sec due to optimal volume-to-surface ratio, fast flow rate and coatings)
  • high frequency measurements (fast electronics allows to collect a single scan at 100 – 1000 Hz)
  • minimal calibration (ultraprecise measurements of several parameters are fed into the in-house algorithm without the use of primary reference methods)
  • rugged systems (design provides more stability towards vibrations, extreme temperatures & measurement drifts through the use of parabolic mirrors)


Nikira Labs instruments are light-weight, require low power and also provide low cost of ownership due to its smart design. Parts that can be subject to long term contamination (filters) and normal aging (pump diaphragm), or that can be exposed to abnormal amounts of contamination during extraordinary events (mirrors), can all be replaced easily, even by untrained personel when need be.  


Nikira Labs analyzers


Nikira Labs Portable Methane Analyzer (PMA)

Fast, accurate measurements of methane in a portable form factor.

  • precision CH4 < 10 ppb (1s, 1s) with a measurement range from 0-1%
  • very compact (23x15x9 cm) and weighs ~2.3 kg with integrated battery (~6 hrs), GPS & WiFi
  • handheld or vehicle-mounted deployment 
  • infrequent calibration required
  • optional bundle: mini-anemometer with visualization plot and emission rate quantification software
  • applications: air quality, atmospheric science, emission monitoring, agriculture & soil science
datasheet



Nikira Labs Portable Methane & Carbon dioxide Analyzer (PMCA)

Fast, accurate measurements of methane and carbon dioxide for soil flux & survey chambers applications.

  • precision CH4 <10 ppb and CO2 <10 ppm (1s, 1s) with a measurement range from resp. 0-1% and 0-2% (data rate 3 Hz)
  • very compact (23x15x9 cm) and weighs ~2.3 kg with integrated battery (~5 hrs), GPS & WiFi
  • handheld or vehicle-mounted deployment
  • infrequent calibration required
  • applications: agriculture & soil science (survey soil chambers applications )
datasheet

 


Nikira Labs High Precision Methane & Carbon dioxide Analyzer (LOMCA)

Fast, accurate and high precision measurements of methane and carbon dioxide for atmospheric applications.

  • precision CH4 <2 ppb and CO2 <0,5 ppm (1s, 1s) with a measurement range from resp. 0-1% and 0-2% (data rate 1 Hz)
  • packaged in Pelican case (56x36x19 cm) and weighs ~8 kg 
  • integrated GPS and WiFi 
  • applications: air quality, atmospheric science, emission monitoring
datasheet



Nikira Labs Methane/Ethane Portable Analyzer (MEPA) 

Fast, accurate measurements of methane and ethane for multiple use cases of natural gas leak detection in a field-deployable & AMLD form factor.

  • precision CH4  <2 ppb and C2H6 <500 ppt (1s, 1s) with a measurement range from resp. 1-100 ppm and 0,001-3 ppm (data rate 2 Hz)
  • Vehicle-mountable for AMLD, compact & light (56x23x14 cm, weight ~4 kg)
  • <30W power use - option for battery power and integrated GPS and WiFi
  • infrequent maintenance / no calibration required
  • applications: air quality, natural gas leaks source identification
datasheet



Nikira Labs Ethylene Oxide (EtO) Analyzer

Fast, accurate, real-time measurements of ethylene oxide at the fenceline.

  • precision C2H4O <2 ppb (1s, 1s) with a measurement range from 1 ppb - 1 ppm (data rate 1 Hz or 2 Hz for mobile apps)
  • compact & light (56x23x14 cm, weight ~4 kg)
  • <30W power use - option for battery power and integrated GPS and WiFi
  • infrequent maintenance / no calibration required
  • applications: air quality, fenceline monitoring
datasheet



Nikira Labs Ammonia Analyzer

High-precision, real-time analysis of ammonia in ambient air & soil flux gas.

  • precision NH3 is 2 ppb (1s, 1s) with a measurement range from 0-3 ppm (data rate 1 Hz)
  • ICOS / CEAS open-path technology
  • integrated battery, GPS and WiFi
  • applications: Airborne Molecular Contamination (AMC) monitoring for semi-conductor industry
datasheet



Semiconductor AMC monitoring 

Real-time, mobile measurements of ammonia, hydrogen fluoride and hydrogen chloride in the FAB Environment.

  • high precision in ppb range (1s, 1s) with a measurement range from 1 ppb - few ppm 
  • compact & light (31x17x28 cm, weight ~2,3 kg)
  • can be used in FOUP or as handheld device
  • applications: air quality, atmospheric science, emission monitoring
datasheet






request information
 
E-mailen
Bellen
Info
LinkedIn